xTool F2 Ultra UV User Guide – EU & UK
Updated Jan 13,2026
Updated Jan 13,2026

Download PDF files (multi-language)

xTool F2 Ultra UV Quick Start Guide

English - Quick Start Guide

Deutsch - Kurzanleitung

Español - Guía de inicio rápido

Français - Guide de démarrage rapide

Italiano - Guida rapida

Nederlands - Korte handleiding

Português - Manual de referência rápida

Polski - Skrócona instrukcja obsługi

日本語 - クイックガイド

한국어 - 빠른 시작 가이드

繁體中文 - 快速入門指南

简体中文 - 快速使用指南

Inner Engraving Pack User Manual

English - User Manual

Deutsch - Benutzerhandbuch

Español - Manual de Usuario

Français - Manuel d'utilisation

Italiano - Manuale utente

Nederlands - Gebruikershandleiding

Português - Manual do Usuário

Polski - Podręcznik użytkownika

日本語 - 取扱説明書

한국어 - 사용자 매뉴얼

繁體中文 - 使用者手冊

简体中文 - 用户手册

xTool F2 Ultra UV unboxing and first use

To ensure proper use, refer to the safety instructions for xTool F2 Ultra UV.

List of items

Item name

Image

xTool F2 Ultra UV

image.png

Touchscreen controller

image.png

Pipe

image.png

Power adapter

image.png

Power cable

image.png

USB cable

image.png

Key

Slatted panel

image.png

L-shaped positioning piece

image.png

Lint-free cloth

image.png

Screwdriver 2.5 mm

image.png

Surface engraving material pack

image.png

Inner engraving pack

Quick start guide

image.png

Safety instructions

image.png

The power cable may vary according to kits. The illustration is for reference only.

Meet xTool F2 Ultra UV

Product structure

image.png

image.png

Reserved port A and reserved port B function differently and can not be used interchangeably.

image.png

By gripping on the handholds, you can easily move the machine.

Touchscreen controller

image.png

Up/Down button for laser module: Lifts or lowers the laser module during manual focusing.

Framing button: Press it once to start or stop framing.

Start/Stop button: Press it once to start or stop material processing; press it twice consecutively to repeat the last processing task.

Common machine states and indicator display

The logo indicator states are described as follows:

image.png

Indicator display

Machine state

image.png

Solid on

Powered on

image.png

Blinking slowly

Processing

image.png

Blinking rapidly

Setting network / Upgrading firmware

image.png

Going off

Sleeping / Powered off

The side indicator states are described as follows:

image.png

Indicator display

Power control components status

Machine state

image.png

Safety indicator: red

Power button indicator: off

Emergency stop button pressed

Powered off

image.png

Safety indicator: off

Power button indicator: off

(1) Emergency stop button released, and reset button not pressed; or (2) Power not connected

Powered off

image.png

Safety indicator: green

Power button indicator: off

Emergency stop button released, reset button pressed, and power button not pressed

Powered off

image.png

Safety indicator: green

Power button indicator: white

Emergency stop button released, reset button pressed, and power button pressed

Powered on

Specifications

Product name

xTool F2 Ultra UV

Model

MXF-K007-003

Working laser

5 W UV laser

Working laser wavelength

355 ± 5 nm

Surface engraving work area

200 mm × 200 mm

Inner engraving work area

70 mm × 70 mm

Maximum processing speed

15,000 mm/s

Connection mode

Wi-Fi, USB, IP

Size (W × D × H)

294 mm × 429 mm × 520 mm

Voltage

110 V / 220 V

Install xTool F2 Ultra UV

1. Detach the field lens protector.

Ensure that the protector is removed every time before you use the machine. If you won't use the machine for a long period of time, you can install the protector back to prevent the field lens from getting dusty.

2. Connect the touchscreen controller.

image.png

Ensure that the side with the notch faces upward.

image.png

3. Connect to a power supply.

image.png

image.png

4. Install the pipe.

image.png

image.png

5. Insert the key.

image.png

You can use the key either as an access-control key or a remote interlock connector.

Access-control key

Removing the key can disable the machine's processing and related functions.

Remote interlock connector

For detailed instructions, click here.

6. Check the emergency stop button.

Ensure that the emergency stop button is released. If it is pressed, rotate to release it.


image.png

Emergency stop button

If an emergency occurs, press the emergency stop button to shut off the machine.

image.png

After dealing with the emergency, rotate the emergency stop button to release it.

7. Press the reset button.

image.png

Use xTool F2 Ultra UV

Power on

Press the power button to turn on xTool F2 Ultra UV.

image.png

For Class 4 laser machines, never use the emergency stop button as a power button.

Use the emergency stop button only when an emergency occurs. Using it as a power button to turn the machine on or off may cause damage.

image.png

To extend the machine’s lifespan, run it at least once a month.

Set the language

Set the UI language on the touchscreen controller.

image.png

Operate xTool F2 Ultra UV with the software

(1) Visit s.xtool.com/software to download and install the software developed by xTool.

(2) Use the USB cable to connect xTool F2 Ultra UV to your computer, and then connect xTool F2 Ultra UV in the software.

image.png

image.png

The other end of the USB cable can be connected to a USB Type-A or Type-C port. Choose between the connectors based on your needs.

image.png


For details about how to use the software to operate xTool F2 Ultra UV to process materials, click here and go to the "Operation & Features" section.

Use accessories

Slatted panel

To cut a material, you are advised to use the slatted panel. It helps reduce burn marks and protects the baseplate during material processing.

image.png

image.png

L-shaped positioning piece

You can use the L-shaped positioning piece for batch processing. It helps you place materials in the same position for each processing task.

image.png

image.png

Maintenance

Disconnect power before maintaining the product.

Clean the field lens

When laser power attenuation occurs, for example, engraved patterns are shallow or materials can't be cut as expected, the field lens may get dirty. Clean it with the lint-free cloth moistened with absolute ethanol.

image.png

image.png

Clean the galvanometer mirrors

After removing the field lens from the device, never touch the two galvanometer mirrors located above it with your hands. Use a lint-free cloth moistened with absolute ethanol to gently clean them only if they appear dirty.

Clean the fan module

When smoke runs out of the protective enclosure, the fan module may be blocked by dust. Clean it to ensure proper smoke exhausting.

(1) Remove the magnetic fan guard from the smoke outlet.

image.png

(2) Open the cover, and then take out the fan module.

image.png

(3) Open the cover to access the fan.

image.png

(4) Use a brush or other tools to clean the fan module and the magnetic fan guard. Then, install them back to the main unit.

image.png

image.png

Do not rinse or immerse the fan module in water, as it may damage the circuit.

It is recommended that you perform the following two key steps at least once a month.

1. Turn on and dry the device for 30 minutes.

Turn on your F2 Ultra UV and keep it running for at least half an hour. This operation allows the device to generate heat while running, automatically drying internal moisture and effectively protecting the UV laser core components that are sensitive to humidity.

2. Check the surfaces of the field lens and the galvanometer mirrors.

Ensure that the surfaces of the field lens and the galvanometer mirrors are clean and free of debris. Dust or dirt on these components can significantly reduce processing quality and may cause degradation or damage.

Why are the above two operations important?

  • Prevent irreversible damage: Your F2 Ultra UV is equipped with a precise ultraviolet laser. If the device remains unused for an extended period—for example, over six months—especially in humid environments, the aging of its critical components, such as the frequency-doubling crystal, could accelerate, potentially leading to irreversible performance degradation.
  • Maintain consistent results: Keeping the field lens and galvanometer mirrors clean is fundamental to achieving optimal processing results.

Other maintenance tips:

  • Use the device in a temperature-controlled environment (10–30°C or 50–86°F).
  • Use the device in a dry and well-ventilated area. Avoid using it in humid environments.
  • If the device will not be used for an extended period, store it in a dry environment.

Dos and don'ts

Surface engraving lens and inner engraving lens replacement

Disconnect power before lens replacement.

Follow the guidelines below for lens replacement.

1. NEVER touch the galvanometer mirrors with your hands! After removing the field lens, under no circumstances should you touch the two galvanometer mirrors inside the device with your hands.

2. The field lens and galvanometer mirrors must be kept absolutely clean.

3. To clean the field lens (surface engraving lens or inner engraving lens), use a lint-free cloth moistened with absolute ethanol.

4. To clean the galvanometer mirrors, use a lint-free cloth moistened with absolute ethanol to gently wipe them only if you confirm the presence of dirt or contamination.

[IMPORTANT] Failure to maintain the cleanliness of the optical components in a timely manner can result in minor issues such as power attenuation, reduced beam quality, and poor processing results, or in severe cases, permanent damage to the optical components!

Slatted panel

The slatted panel serves to provide support, guide airflow, and protect the device’s baseplate during use. When engraving thin or transparent materials, use the slatted panel to avoid damaging the device’s baseplate.

Riser for inner engraving

The riser for inner engraving serves as a support and positioning tool during use. During the inner engraving process of a glass workpiece, if the engraved model is low and the focal point is close to the riser top plate, there is a risk of damage to the riser top plate. Please use it with caution.

Emergency stop button

The emergency stop button is used to cut off the device's power supply in emergency situations. Do not use the emergency stop button as the device's power button.

More information

Safety First for xTool F2 Ultra UV (EU & UK)

xTool F2 Ultra UV LSO Training


Preview
Was this page helpful?
3 out of 3 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
xTool Logo

Contact Us

🇺🇸+1 (888) 528-2293
Service Live Chat

Copyright © 2025 xTool All Rights Reserved.