Processing Mode | Focusing Range (mm) | XCS Auto-Measure Range (mm) |
---|---|---|
Process on Baseplate | 0~16 | 0~16 |
Roller/Chuck - Use Rotary Attachment | -19~16 | 0~34 |
Baseplate Removed | -19~16 | 0~34 |
Blade Cut | No Focusing Required | No Measurement Required |
Honeycomb Panel Position | Suitable Material Thickness (Baseplate Removed) | Suitable Material Circumference (Roller - Use Rotary Attachment) | Suitable Material Circumference (Chuck - Use Rotary Attachment) |
---|---|---|---|
TOP | 0~13mm | Unable to process | Unable to process |
α | 30~65mm | 0 ~ 88mm | Unable to process |
β | 60~90mm | 88~ 220mm | 0 ~142mm |
γ | 90~120mm | 220~299mm | 142~314mm |
If the material size for processing is not included in the table, adjust the material height to ensure the processing surface is within the focusing range while making sure M1 is placed steadily during processing.
📌 Important note
- The data in this guide reflects theoretical values. Actual parameters may vary due to assembly tolerances, measurement inaccuracies, or flatness irregularities.
- Always verify material placement and focus alignment before beginning processing.
If this article or video doesn't effectively assist you in resolving the issue, please let us know by clicking the “No” button in the “Was this page helpful?” section below, and leave your feedback in the pop-up suggestion box. Our knowledge base team will review it and consider it for future updates.